| Availability: | |
|---|---|
| Gentier 96E | Gentier 96R | |
| Thermal Block | ||
| Sample capacity(wells) | 96 | |
| Reaction Volume | 0-100 uL | |
| Consumables | 0.2ml 96 well Plates (unskirt) ; 0.2ml 8 strip tubes,0.2ml PCR single tube(Optical flat cap,clearffrosted,white tube) | |
| Temperature range | 0°C-100°C | |
| Heating/cooling method | Peltier | |
| Max heating rate | 6.1°C/sec | |
| Average heating rate | 4.5°C/sec | |
| Max cooling rate | 5.0°C/sec | |
| Average cooling rate | 2.8°C/sec | |
| Temperature accuracy | ±0.1°C | |
| Temperature uniformity | ±0.1°C | |
| Gradient Range | 1 °C-40°C | 1 °C-40°C |
| Gradient block | 12 row | 12 row |
| Special temperature protocol | Gradient PCR..Long PCRlbuch Down PCR | Gradient PCR,Long PCR touch Down PCR |
| Heat Lid | ||
| Temperature range | Room Temperature-110uC | |
| Optical System | ||
| Excitation Source | 6LEDs | 4LEDs |
| Detector | Photodiode | |
| Detection Position | Excitation and scan at top | |
| Detection method | 6 channels scanning at the same time, no edge effect. | |
| Detection time | 7 seconds for 96 wells for all channels | |
| Range of excitation/ emission wavelengths(nm) | 1.465 /510(FAM,SYBR Green I SYTO9,EvaGreenrLC Green) 2.527/ 563 (HEX.VIC,TET,JOE) 3.580 /616 (ROX,Texas Red) 4.632/ 664( Cy5) 5.680/730 (Alexa Fluor680) 6.465 Z616 (FRET) | 1.465 /510 (FAM,SYBR Green l,SYTO9,EvaGreen,LC Green) 2.527/ 563 (HEX,VIC,TET,JOE) 3.580 /616 (ROX,Texas Red) 4.632/ 664( Cy5) |
| Probe | Taqman Probe.Molecular beacons probe,Scorpion probe ,FRET | Taqman Probe,Molecular beacons probe,Scorpion probe |
| Multiplexing | Up to 6 targets | Up to 4 targets |
| Fluorescence Linearity | r≥0.990 | |
| Fluorescence Dynamic Range | Adjustable | |
| Performance | ||
| Sample Linearity | /r/≥0.999 | |
| Sample repeatability | Ct value CV≤0.5% | |
| Sample Dynamic Range | 1-1 010 copies | |
| Software Functions | ||
| Data Analysis modes | Qualitative analysis,Absolute quantification, Relative quantification,Genotyping analysis.Endpoint analysis, Melt curve analysis | |
| Control modes | 1.10.4" touch screen 2. PC direct control 3. WLAN control(One PC can control max 10 units, and device can be controled by any PC in the WLAN) | |
| Data Storage | Upload and download through USB disk 1000 results can be stored in machine | |
| Power failure protection | Automaticly start running experiments after power supply, no need wail PC software | |
| Customize Report | Templetes reserved ^report can customized | |
| Administration Management | Administrator can set functions limits for users | |
| Fault Management | Fault report and analysis, solution instruction | |
| LIS connection | CSV.Excel,TXT format data output.open port for LIS connection | |
| Others | ||
| PC operating system | Win 7, Win 10 | |
| Communication Port | 1 ethernet and 3 USB | |
| Footprint(WxDxH) | 355mm X 480mm X 485mm | |
| Weight | 30kg | |
| Power usage | AC 100 to 125 V/200 to 240 V (50/60 Hz). | |
| power consumption | 900VA | |
| Work environment | Temperature: 10°C -30°C Humidity:20%~85% | |
| Gentier 96E | Gentier 96R | |
| Thermal Block | ||
| Sample capacity(wells) | 96 | |
| Reaction Volume | 0-100 uL | |
| Consumables | 0.2ml 96 well Plates (unskirt) ; 0.2ml 8 strip tubes,0.2ml PCR single tube(Optical flat cap,clearffrosted,white tube) | |
| Temperature range | 0°C-100°C | |
| Heating/cooling method | Peltier | |
| Max heating rate | 6.1°C/sec | |
| Average heating rate | 4.5°C/sec | |
| Max cooling rate | 5.0°C/sec | |
| Average cooling rate | 2.8°C/sec | |
| Temperature accuracy | ±0.1°C | |
| Temperature uniformity | ±0.1°C | |
| Gradient Range | 1 °C-40°C | 1 °C-40°C |
| Gradient block | 12 row | 12 row |
| Special temperature protocol | Gradient PCR..Long PCRlbuch Down PCR | Gradient PCR,Long PCR touch Down PCR |
| Heat Lid | ||
| Temperature range | Room Temperature-110uC | |
| Optical System | ||
| Excitation Source | 6LEDs | 4LEDs |
| Detector | Photodiode | |
| Detection Position | Excitation and scan at top | |
| Detection method | 6 channels scanning at the same time, no edge effect. | |
| Detection time | 7 seconds for 96 wells for all channels | |
| Range of excitation/ emission wavelengths(nm) | 1.465 /510(FAM,SYBR Green I SYTO9,EvaGreenrLC Green) 2.527/ 563 (HEX.VIC,TET,JOE) 3.580 /616 (ROX,Texas Red) 4.632/ 664( Cy5) 5.680/730 (Alexa Fluor680) 6.465 Z616 (FRET) | 1.465 /510 (FAM,SYBR Green l,SYTO9,EvaGreen,LC Green) 2.527/ 563 (HEX,VIC,TET,JOE) 3.580 /616 (ROX,Texas Red) 4.632/ 664( Cy5) |
| Probe | Taqman Probe.Molecular beacons probe,Scorpion probe ,FRET | Taqman Probe,Molecular beacons probe,Scorpion probe |
| Multiplexing | Up to 6 targets | Up to 4 targets |
| Fluorescence Linearity | r≥0.990 | |
| Fluorescence Dynamic Range | Adjustable | |
| Performance | ||
| Sample Linearity | /r/≥0.999 | |
| Sample repeatability | Ct value CV≤0.5% | |
| Sample Dynamic Range | 1-1 010 copies | |
| Software Functions | ||
| Data Analysis modes | Qualitative analysis,Absolute quantification, Relative quantification,Genotyping analysis.Endpoint analysis, Melt curve analysis | |
| Control modes | 1.10.4" touch screen 2. PC direct control 3. WLAN control(One PC can control max 10 units, and device can be controled by any PC in the WLAN) | |
| Data Storage | Upload and download through USB disk 1000 results can be stored in machine | |
| Power failure protection | Automaticly start running experiments after power supply, no need wail PC software | |
| Customize Report | Templetes reserved ^report can customized | |
| Administration Management | Administrator can set functions limits for users | |
| Fault Management | Fault report and analysis, solution instruction | |
| LIS connection | CSV.Excel,TXT format data output.open port for LIS connection | |
| Others | ||
| PC operating system | Win 7, Win 10 | |
| Communication Port | 1 ethernet and 3 USB | |
| Footprint(WxDxH) | 355mm X 480mm X 485mm | |
| Weight | 30kg | |
| Power usage | AC 100 to 125 V/200 to 240 V (50/60 Hz). | |
| power consumption | 900VA | |
| Work environment | Temperature: 10°C -30°C Humidity:20%~85% | |