1. The height of the air chamber plate can be adjusted. The length of a standard gas needle
is 150mm.
2. LED displays immediate temperature and diminishing time. Operation is simple and convenient.
3. Built in overheat protection, automatic fault detection and fault beep alarm devices.
4. The entire equipment can be put into ventilation cabinet when the concentration sample is in
toxic solvents.
5. Synchronously working with heating by dry bath in the bottom and nitrogen blowing on the
surface accelerates liquid evaporation and sample concentration.
6. Unique patented design for air channel control system, enhances air tightness and reduces
potential leakage; easy to operate, lift/press air needle to realize channel
switch; the switching
status of each channel is clear at a glance.
7. Standard configured air cavity and adjustable bracket.
Parameters
Model | NDK200-1N | NDK200-2N |
Temp. Control Range | R.T.+5°C~150°C | R.T.+5°C-150°C |
Temp. Setting Range | 5°C -150°C | 5°C -150°C |
Temp. Stability@40~100°C | ±0.5°C | ±0.5°C |
Temp. Stability@100-150°C | ±1°C | ±1°C |
Block Temp. Uniformity@100°C | ±0.5°C | ±0.5°C |
Block Temp. Uniformity@150°C | ±1°C | ±1°C |
Temp. Display Accuracy | 0.1°C | 0.1°C |
Heating Speed | ≤30min (40°C to 150°C) | ≤30min(40°C to 150°C) |
Time Range | lmin-99h59min | lmin-99h59min |
Needle Plate Max. Lift Stroke | 285mm | 285mm |
Gas-in Joint Outer Diameter | 07mm | 07mm |
Nitrogen Pressure | ≤0.1MPa | ≤0.1MPa |
Nitrogen Flow Rate | 0 -10L/min | 0 -10L/min |
Needle Length | 150mm | 150mm |
Sample Capacity | 1 standard block | 2 standard blocks |
Voltage | AC 220V/AC110V, 50/60Hz | AC 220V/AC110V, 50/60Hz |
Power | 200W | 400W |
Fuse | 250V, 2A/3A, Φ5X20 | 250V, 3A/6A, Φ5X20 |
Dimension (WxDxH) | W.200xD.230xH.525mm | W.200xD.260xH.525mm |
Net Weight | 5.1kgs | 6.1kgs |
1. The height of the air chamber plate can be adjusted. The length of a standard gas needle
is 150mm.
2. LED displays immediate temperature and diminishing time. Operation is simple and convenient.
3. Built in overheat protection, automatic fault detection and fault beep alarm devices.
4. The entire equipment can be put into ventilation cabinet when the concentration sample is in
toxic solvents.
5. Synchronously working with heating by dry bath in the bottom and nitrogen blowing on the
surface accelerates liquid evaporation and sample concentration.
6. Unique patented design for air channel control system, enhances air tightness and reduces
potential leakage; easy to operate, lift/press air needle to realize channel
switch; the switching
status of each channel is clear at a glance.
7. Standard configured air cavity and adjustable bracket.
Parameters
Model | NDK200-1N | NDK200-2N |
Temp. Control Range | R.T.+5°C~150°C | R.T.+5°C-150°C |
Temp. Setting Range | 5°C -150°C | 5°C -150°C |
Temp. Stability@40~100°C | ±0.5°C | ±0.5°C |
Temp. Stability@100-150°C | ±1°C | ±1°C |
Block Temp. Uniformity@100°C | ±0.5°C | ±0.5°C |
Block Temp. Uniformity@150°C | ±1°C | ±1°C |
Temp. Display Accuracy | 0.1°C | 0.1°C |
Heating Speed | ≤30min (40°C to 150°C) | ≤30min(40°C to 150°C) |
Time Range | lmin-99h59min | lmin-99h59min |
Needle Plate Max. Lift Stroke | 285mm | 285mm |
Gas-in Joint Outer Diameter | 07mm | 07mm |
Nitrogen Pressure | ≤0.1MPa | ≤0.1MPa |
Nitrogen Flow Rate | 0 -10L/min | 0 -10L/min |
Needle Length | 150mm | 150mm |
Sample Capacity | 1 standard block | 2 standard blocks |
Voltage | AC 220V/AC110V, 50/60Hz | AC 220V/AC110V, 50/60Hz |
Power | 200W | 400W |
Fuse | 250V, 2A/3A, Φ5X20 | 250V, 3A/6A, Φ5X20 |
Dimension (WxDxH) | W.200xD.230xH.525mm | W.200xD.260xH.525mm |
Net Weight | 5.1kgs | 6.1kgs |