20 tests/kit
Hunan Runmei Gene
L/C, T/T, D/P, Western Union, Paypal
CE, ISO 13485
Rapid Test Kit / One-step Test Kit / Rapid Detection Test
Availability: | |
---|---|
SARS-CoV-2(COVID-19) Saliva Antigen Rapid Test Kit(Lollipop Design)
This kit is intended to be used for the qualitative detection of SARS-CoV-2 antigen in human respiratory specimens, sputum and other samples. This kit uses cellulose membrane immunochromatography technology. Antigen detection is used for auxiliary diagnosis or epidemiological investigation of human infection with SARS-CoV-2.
Antigen Rapid Detection Kit Parameters
Test Card,Disposable sampling tube(with sample diluent buffer),Disposable sampler
【KIT COMPONENTS】
Komponenten | 1T | 20T | 30T | 50T |
SARS-CoV-2 Testkarte | 1 Stück | 20 Stück | 30 Stück | 50 Stück |
Anweisungen | 1 Kopie | 1 Kopie | 1 Kopie | 1 Kopie |
Hinweis: Die Komponenten in den Kits verschiedener Chargennummern sind nicht austauschbar. |
New coronavirus antigen test card Features:
1. Sensitivity
(1)The concentration of recombinant N protein of the new coronavirus can be detected as low as 0. lng/ml.
(2) The concentration of inactivated virus lysate can be detected as low as 10ng/ml, and the sensitivity is
105-6 copies/ml.
(3)Twenty-six cases were detected in 30 throat swab samples of the new coronavirus, with a detection rate
of86.7%.
2. Specificity
(1)No false positives were found in100 throat swabs from healthy people.
(2) No cross reaction with influenza A virus, infuenza B virus, Mycoplasma pneumoniae, respiratory
syncytial virus, etc.
SARS-CoV-2(COVID-19) Saliva Antigen Rapid Test Kit(Lollipop Design)
This kit is intended to be used for the qualitative detection of SARS-CoV-2 antigen in human respiratory specimens, sputum and other samples. This kit uses cellulose membrane immunochromatography technology. Antigen detection is used for auxiliary diagnosis or epidemiological investigation of human infection with SARS-CoV-2.
Antigen Rapid Detection Kit Parameters
Test Card,Disposable sampling tube(with sample diluent buffer),Disposable sampler
【KIT COMPONENTS】
Komponenten | 1T | 20T | 30T | 50T |
SARS-CoV-2 Testkarte | 1 Stück | 20 Stück | 30 Stück | 50 Stück |
Anweisungen | 1 Kopie | 1 Kopie | 1 Kopie | 1 Kopie |
Hinweis: Die Komponenten in den Kits verschiedener Chargennummern sind nicht austauschbar. |
New coronavirus antigen test card Features:
1. Sensitivity
(1)The concentration of recombinant N protein of the new coronavirus can be detected as low as 0. lng/ml.
(2) The concentration of inactivated virus lysate can be detected as low as 10ng/ml, and the sensitivity is
105-6 copies/ml.
(3)Twenty-six cases were detected in 30 throat swab samples of the new coronavirus, with a detection rate
of86.7%.
2. Specificity
(1)No false positives were found in100 throat swabs from healthy people.
(2) No cross reaction with influenza A virus, infuenza B virus, Mycoplasma pneumoniae, respiratory
syncytial virus, etc.
Assay Procedure of New Coronavirus COVID-19 Antigen rapid test kit
Please read the instruction for use carefully before using this kit. All reagents should be incubated at room temperature (10-30°C) for 30 minutes prior to use. The test should be carried out at room temperature and the operation procedure is described below:
1.Open the sealed bag and remove the Detection Strip. Mark the sample ID on the test strip and lay the strip flat on the table.
2. Specimen collection
1).Carefully insert the swab into the nostril of the patient, reaching the surface of posterior nasopharynx, that presents the most secretion under visual inspection.
2).Swab over the surface of the posterior nasopharynx. Rotate the swab several times.
3).Withdraw the swab from the nasal cavity.
3.Sample preparation
1). Insert the sample diluent tube into the pipe rack, make sure that the tube is standing firm and reaches the bottom of the pipe rack.
2). Open the purple cap of the sample diluent tube. Insert the swab into the diluent tube which contains 0.5 mL of the diluent buffer. Roll the swab at least 6 times while pressing the head against the bottom and side of the diluent tube.
3). Leave the swab in the diluent tube for 1 minute.
4). Squeeze the tube several times with fingers from outside of the tube to immerse the swab. Remove the swab,close the cap. The diluent solution will be used as test sample.
5). Open the small cap on the top of the sample dilution tube. Add 3-4 drops (~100 μL) of the sample diluent buffer immediately to the sample well.
6). Allow the strip to develop for 10-15 minutes at room temperature. A visible band can be read by naked eyes.
Assay Procedure of New Coronavirus COVID-19 Antigen rapid test kit
Please read the instruction for use carefully before using this kit. All reagents should be incubated at room temperature (10-30°C) for 30 minutes prior to use. The test should be carried out at room temperature and the operation procedure is described below:
1.Open the sealed bag and remove the Detection Strip. Mark the sample ID on the test strip and lay the strip flat on the table.
2. Specimen collection
1).Carefully insert the swab into the nostril of the patient, reaching the surface of posterior nasopharynx, that presents the most secretion under visual inspection.
2).Swab over the surface of the posterior nasopharynx. Rotate the swab several times.
3).Withdraw the swab from the nasal cavity.
3.Sample preparation
1). Insert the sample diluent tube into the pipe rack, make sure that the tube is standing firm and reaches the bottom of the pipe rack.
2). Open the purple cap of the sample diluent tube. Insert the swab into the diluent tube which contains 0.5 mL of the diluent buffer. Roll the swab at least 6 times while pressing the head against the bottom and side of the diluent tube.
3). Leave the swab in the diluent tube for 1 minute.
4). Squeeze the tube several times with fingers from outside of the tube to immerse the swab. Remove the swab,close the cap. The diluent solution will be used as test sample.
5). Open the small cap on the top of the sample dilution tube. Add 3-4 drops (~100 μL) of the sample diluent buffer immediately to the sample well.
6). Allow the strip to develop for 10-15 minutes at room temperature. A visible band can be read by naked eyes.