Home / Products / Disposable samplers / Disposable Swab with Viral Transport Tube (UTM/VTM/MTM/Amies)

loading

Share to:
sharethis sharing button

Disposable Swab with Viral Transport Tube (UTM/VTM/MTM/Amies)

  • 30 tests/kit &40 tests/kit &50 tests/kit & 400 tests/kit

  • Hunan Runmei Gene

  • 3822009000

  • CE, ISO 13485, FDA

  • Throat swab / Nasal Swab / Nasopharyngeal Swabs / Oropharyngeal Swabs / Oral Swabs / Mouth Swabs

Availability:

Product Description

Disposable Swab with Viral Transport Tube (UTM/VTM/MTM/Amies) is designed for collection, transportation and short-time storage of total DNA/RNA in clinical specimens such as saliva, blood, serum, stool and body fluid, etc. The stored samples can be used in subsequent clinical experiments such as DNA/RNA extraction, PCR testing or sequencing. The kit is ideal for collecting specimens for coronavirus identification and downstream studies.


Disposable viral transport tube is the preferred transport media to maintain the specimen stability, for Covid-19 clinical specimens collection, storage and transport. VTM, UTM, MTM, Amies Medium are optional for virus preservation fluid. Flocked Swabs has a superior specimen collection and release ability,due to the unique spray type nylon pile implantation technology.


Disposable Swab with Viral Transport Tube (UTM/VTM/MTM/Amies) Features

1. Activated and Inactivated for choose.

2. Convenient one-stop sample collection, transport and storage kit.

3. High sample efficiency, due to the unique spray type nylon pile implantation technology.

4. Medical grade ABS swabstick,easily breakable and no interfere with viral PCR testing.

5. Individually wrapped and sterile.

6. Easy to operate and ready to use.

7. Rapid sampling time.

8. CE , FDA certified.


Disposable Swab with Viral Transport Tube (UTM/VTM/MTM/Amies) Operating Instruction


Specifications and models

Name

Number

Packing unit

Single-use samplers

50

Kit
Plastic tube (Contain preservation solution) 50 Kit


Weight Volume

standard: 10ML tube + a throat swab + a nose swab

Unit

Piece

Volume(CM)

Weight(KG)

per box

50

21*11*16.5

0.65

per carton

20*50

57.5*44*35

14.7

per pallet

24*20*50

132*115*140

352.8

standard: 10ML tube + a throat swab or a nose swab

Unit

Piece

Volume(CM)

Weight(KG)

per box

50

21*11*14

0.6

per carton

20*50

57.5*44*30

13.6

per pallet

24*20*50

132*115*120

326.4


Packing Specification

30 Testing / box & 50 Testing / box & 400 Testing / box


Intended Use of Disposable Swab with Viral Transport Tube (UTM/VTM/MTM/Amies)

Itis used for the collection and transportation of cdinical infuenza, avian influenza, hand, foot and mouth disease, measles and other virus specimens, as well as chlamydia, mycoplasma and ureaplasma specimens.


Main Components

Number Composition 30 Testing/box 50 Testing/box 400 Testing/box
1 Sampling Tube (with 3ml sampling solution) 3ml x 30tube 3ml x 50tube 3ml x 400tube
2 SamplingSwab 30 pcs/box 50 pcs/box 400 pcs/box
3 Manual 1 serving 1 serving 1 serving


Storage Condimtions

Store at nommal temperature 5 -25°C.


Sample Requirements

1. Applicable sample types: Pharyngeal swabs, nasopharyngeal swabs, saliva, sputum and other clinical samples.

2. Storage and transportation of samples: After the sample is collected, it should be transported to the corresponding laboratory for testing within 48 hours, and the storage temperature is 2-8 °C. If it cannot be transported to the laboratory within 48 hours, it should be stored at -80 °C or below and sent to the corresponding laboratorywithin one week. The sample should avoid repeated freezing and thawing.


Precautions

1. Single-use samplers should be sent for inspection as soon as possible after sampling, and immediately be transported at a low temperature of 2-8°C. The collected samples can be stored at 2-8 °C for a short period of 48 hours, long-term storage should be placed in low temperature conditions below -20°C, -70°C or store at -196°C

2. This single use sampler is strictly prohibited for the sampling ofbacterial samples. The antibiotics contained in the preservation solution itself have an inhibitory effect on bacteria.

3. It is forbidden to directly touch the collected patient, or to sample the patient after wetting the swab.

4. Sampling should be carried out in strict accordance with the sampling procedure, so that the sampling location is accurate and the sampling strength is uniform and suitable, otherwise it will affect the quality of sample collection.

5. Don't use the disposable sampler after the expiration date or the product packagingis damaged.


Expiration Data

12 months


Single-use Simplers Product Classification

single-use simplers product classification

Single-use Simplers Instruction for Use


intruction for use

Previous: 
Next: 

Hunan Runmei Gene Technology Co.,LTD

Company Address: Room 401, Building No.3 in Changsha Medical 
and Health Industrial Park, No.1048 Zhong Qing Road, Kai Fu 
District, Changsha,  Hunan Prov., P.R. China
Email: sales@runmeigene.com
Tel:(+86)-731-89919680 /(+86)-18601451556

MENU

© 2020 Runmei. All rights reserved.