Home / Products / Covid-19 Series Products / New Coronavirus COVID-19 Freeze-Dried Lyophilised PCR Mixes

loading

Share to:
sharethis sharing button

New Coronavirus COVID-19 Freeze-Dried Lyophilised PCR Mixes

  • 50 tests/kit & 100 tests/kit

  • Hunan Runmei Gene

  • L/C, T/T, D/P, Western Union, Paypal

  • CE, ISO 13485

  • RT-PCR Kit / Real Time PCR Kit / RT-PCR Fluorescence Detection Kit,Freeze-Dried PCR Mixes,Lyophilised PCR Mixes,pcr,PCR Mixes

Availability:

Freeze-Dried Lyophilised PCR Mixes Description:

This kit is used for the detection of COVID-19 (ORF lab/N Gene) Nucleic Acid and assisted diagnosis and epidemiological surveillance of COVID-19.


Lyophilised PCR Mixes Composition:

COVID-19 PCR Mix、Resuspension Buffer、COVID-19 Negative Control、COVID-19 Positive Control


Package Instruction:

50 tests/kit & 100 tests/kit


Packing: Paper、Foil pouch


Storage Temperature: -20±5℃


Period of Validity: 6 Months


Freeze-Dried Lyophilised PCR Mixes Features

1. Multiplex One-step RT Real-time PCR assay for reliable test result.

2. Good performance with high sensitivity and specificity co-developed and testified

by Wuhan Institute of Virology, Chinese Academy of Sciences.

3. Compatible with varied Real-time PCR systems.

4. Sensitivity:2500 copies/mL, Reaction time: 1h. 

5. Low requirements for transportation environment

6. Low transportation cost of products


Specifications and Models:

Name

Number

Packing unit

New Coronavirus COVID-19 Freeze-Dried Lyophilised PCR Mixes

50 or 100 tests

Box


Weight Volume of Real Time PCR Detection Kit:

Unit

Piece

Volume(CM)

Weight(KG)

per box

50

5.5*5.5*5.5

0.025

per carton

80*50

65*40*45

4.35

per pallet

14*80*50

120*105*135

60.9


New Coronavirus COVID-19 Freeze-Dried Lyophilised PCR Mixes Result Judgment:

1. If the test sample detects a typical S-type amplification curve in the FAM and

HEX channels and the Ct value is <40, and there is a typical S-type amplification curve

in the Internal Control channel (Cy5), the sample can be judged to be COVID-19

positive. 

2. If the test sample has no amplification curve or Ct value> 40 in the FAM and HEX

channels, and there is a typical S-type amplification curve in the Internal Control

channel (Cy5), the sample can be judged to be COVID-19 negative.

3. If the test sample only has a Ct value≤40 in a single channel of the FAM or HEX

channel, and there is a typical S-type amplification curve in the Internal Control channel

(Cy5), the results need to retest. If the results repeated are consistent, the sample can be

judged as COVID-19 positive, the results repeated are negative except for the typical S-

type amplification curve of the Internal Control channel (Cy5), which could be judged

as COVID-19 negative.

4. If no typical S-type amplification curve (No Ct value) or Ct value> 40 is detected

in the FAM, HEX, and Cy5 channels of the test sample, it means that there is a problem

with the quality of the sample or a problem with the operation. If the result is invalid,

you should find and eliminate the cause, collect the sample again, and repeat the test (if

the test result is still invalid, please contact the company).



Previous: 
Next: 

Hunan Runmei Gene Technology Co.,LTD

Company Address: Room 401, Building No.3 in Changsha Medical 
and Health Industrial Park, No.1048 Zhong Qing Road, Kai Fu 
District, Changsha,  Hunan Prov., P.R. China
Email: sales@runmeigene.com
Tel:(+86)-731-89919680 /(+86)-18601451556

MENU